How the calculator works
It uses LG's UAE room table for a 2.8 m ceiling. Up to 120 sq ft is 1 ton, 120 to 180 sq ft is 1.5 ton, 180 to 220 sq ft is 1.5 to 2 ton, 200 to 250 sq ft is 2 ton and 250 to 350 sq ft is 2.5 ton. Where two bands overlap we use the smaller size. LG adds half a ton for west-facing rooms and says top floors often need one step up.
We apply one step up at most, even if the room is both west facing and on the top floor. The Abu Dhabi Department of Energy found that ACs are often oversized by 25 to 35%, and an oversized unit costs more to buy and to run.
| Room | Floor area | Size |
|---|---|---|
| Small room | up to 120 sq ft | 1 ton |
| Bedroom | 120 to 180 sq ft | 1.5 ton |
| Large bedroom | 180 to 220 sq ft | 1.5 to 2 ton |
| Living room | 200 to 250 sq ft | 2 ton |
| Majlis | 250 to 350 sq ft | 2.5 ton |
Rooms over 350 sq ft
Large living rooms, open plan spaces and halls usually need two units, a floor-standing unit or a ducted system. The calculator flags them for a survey instead of guessing.
Tons and BTU
One ton of cooling is 12,000 BTU per hour, so 1.5 ton is 18,000 BTU/h and 2 ton is 24,000 BTU/h. Labels show both.
Questions
1.5 ton AC is for what room size
In LG's UAE guide, 1.5 ton covers a room of 120 to 180 sq ft, and rooms of 180 to 220 sq ft need 1.5 to 2 ton. West-facing rooms get half a ton more.
2 ton AC is for what room size
LG's UAE guide gives 2 ton for a living room of 200 to 250 sq ft, with a 2.8 m ceiling.
Why do UAE sizing guides disagree
Daikin's UAE villa guide starts from 20 to 30 BTU per sq ft, while LG's room table works out near 100 BTU per sq ft. Room tables include the Gulf sun, glass and outdoor heat that a simple rate leaves out. A survey settles it for your room.